Low suction pressure high head pressure - Jun 29, 2009 · Peal. 3 posts · Joined 2009. #46 · Jul 12, 2009 (Edited) I think bwalley is correct. 3 things will cause high head pressure; poor air flow across condenser, overcharge, or non condensable in system. Recover charge, check system for leaks, pull vacuum, and weigh in new charge.

 
The human heart creates a pressure within the circulatory system every time it beats. Some people experience periods where their blood pressure is too high or too low. When blood M.... Z1 intakes

This restriction will result in a pressure drop across the restriction. You'll have higher pressure on the inlet side and lower pressure on the outlet side of the “traffic jam.” ... we will see low suction pressure, high superheat, and normal to high subcooling. (Note: high head pressure isn't typically an indicator of a restriction!) In ...My suction is running at 45psi and head is at 110psi. I checked evap coil and filter and both were clean, so I figured it was low on R22. I added 7 lbs. (factory charge is 7.25 lbs) and pressures did not change. The suction line is frosting up to the compressor. I'm starting to think I have a bad reversing valve.Took a reading off one of our units that cool an elevator machine room. It's an old Carrier 10 ton unit, single compressor, water cooled tube in tube condenser. Suction pressure was good at 68 , head pressure went over 300 and was tripping it out. Cleaned the strainer, same thing happens. Brought in a mechanic who says the TEV is bad and is …The Net Positive Suction Head (NPSH) margin is a crucial factor that is commonly overlooked while selecting a pump. ... Pumps work by creating a pressure differential between the inlet and the outlet—the high pressure at the inlet causes fluid to flow towards the low pressure at the outlet. As the fluid flows through the pump, it …Cause #1 Return Duct Leakage:. The suction pressure can be high if the room temp is high, or the return duct has leaks. Cause #2 TXV Improperly feeding: Cause#3 Outdoor/Indoor coil dirty: low airflow situations can cause refrigerant to not completely condense into a liquid, or turn into a gas Cause #4 Unit is Overcharged: One …Watch on. Compression ratio is the ratio of head pressure to suction pressure in an HVAC/R unit. Generally, compression ratios approach 2.5:1 on high-efficiency, 16+ SEER A/C systems. The highest compression ratio in A/C compressors is typically 11:1. Refrigeration compression ratios tend to be quite a bit higher (up to 26:1).High head pressure B. High liquid level C. Low head pressure D. Low suction pressure A. High head pressure What is the typical design burst pressure for a rupture disk on a low-pressure centrifugal air-conditioning system.HVAC REFRIGERATION TROUBLESHOOTINGLOW SUCTION/LOW HEAD PRESSURE1. check air flow obstruction2. check dirty evaporator3. check dirty air filter4. check for a ...If a high head pressure is detected, you will need to call your local professionally licensed air conditioning service team. What Determines High Head Pressure. A 410A system who have 400-418 PSIG on the high side, while the lower side is 120-130 PSI. If it is more than this, it is considered high.Definition. of NPSH —The margin of pressure over vapor pressure, at the pump suction nozzle, is Net Positive Suction Head (NPSH). NPSH is the diference between suction …Yeah I'm pretty sure it's an cfm flow because the furnace is a 90,000 btu furnace but I did put it on low speed still wondering if maybe it's still too much flow considering how big it is for only 1,000 sqft house..Jul 25, 2011 · High discharge temperatures can indicate minimal movement of refrigerant. Because the refrigerant isn't being pumped at design rates it stays in the condenser for a longer period of time and is cooled more, hence lower head pressures, and in turn, if the compressor is not pumping well, you will see elevated suction pressures. Reply. I just wanted to pick every ones brain i could. I am working on trane condensor and have high head pressure and low suction pressure. It was 90+ out today and I dumped r-22 into the system and no matter what I did I could not get the suction line to sweat and the superheat never dropped below about 20 degrees. my head pressure …A cold suction line (low superheat) with low suction pressure is a symptom of low evaporator air. A liquid restriction would result high superheat (warm suction line). The high head probably due to the other guys overcharging, trying to get the suction pressure up.In this HVAC Refrigerant Charging Video I go over what it means to have low R22 Freon or Low R410A Suction Vapor Pressure along with a Low Superheat. I expla...KITCO NEWS -- Gold slightly pressured Tuesday, and iiTrader’s senior strategist Bill Baruch says it's because of the downward pressure lower copper and crude prices are having ...91. If the head pressure is too high: A. the relief valve should open and let excess refrigerant pass to receiver. B. close in on the suction valve. C. the relief should open before the high-pressure cutout. D. the high-pressure cutout switch should operate before the relief value opensR410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.Keeping your shower head clean is essential for maintaining good hygiene and ensuring a steady water flow. Over time, mineral deposits and bacteria can build up, causing clogs and ...I arrive to find a loud compressor, 200 psi suction and 275 head. First thing that comes to mind is bad valves. A few minutes later the compressor cuts off on internal overload. I take a hose and cool it off. 10 min later, compressor kicks back on and pressures now seem normal (130/325) 13 subcool , 19 delta t.404a pressures in low. I have a r-404a roof-top condensing serving a walk in freezer. pressures are 235 psi head pressure and a 28psi suction pressure. Outdoor ambient is 30degress and indoor box temperature is about 20degrees. System has a head pressure control on roof for hot gas. Wondering if pressures sound right.Jul 20, 2021 · An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ... Low suction pressure/low superheat: Apart from refrigerant leaks causing loss of critical charge, the most common problem associated with low suction pressure is: …High head pressure B. High liquid level C. Low head pressure D. Low suction pressure. A. High head pressure. What is the typical design burst pressure for a rupture disk on a low-pressure centrifugal air-conditioning system. A. 5 psig B. 10 psig C. 15 psig D. 20 psig. C. 15 psig.Discover expert tips for troubleshooting well water issues, including low pressure and discoloration. Keep your water flowing smoothly with practical solutions. Expert Advice On Im...Figure 5 The effect of low level on the pump suction. The pump will still produce the same total head but the discharge head will go down. This means you may not have enough pressure to run your devices and you may need to consider getting a pump with a higher total head. ... After all if you have a high head, which means a high pressure ...Suction Head. Based on the Energy Equation - the suction head in the fluid close to the impeller *) can be expressed as the sum of the static and velocity head: h s = p s / γ liquid + v s 2 / 2 g (1) where. h s = suction head close to the impeller (m, in) p s = static pressure in the fluid close to the impeller (Pa (N/m 2), psi (lb/in 2))Bombogenesis happens when the atmospheric pressure in a low-pressure system drops rapidly, intensifying a storm and creating a bomb cyclone. Advertisement This planet has a lot of ...• At the rupture disc seal. • Around the vent valve. • Around a test plug • In the drain valve opening., 2. Which of the following indicates air in a low-pressure system? • High head pressure • High liquid level • Low head pressure • Low suction pressure, 3. A hydrostatic tube test kit will: • determine if a tube leaks.Jul 19, 2005 · In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet. The Cost of High Head Pressure. January 5, 2001. Table 1. Based on recopricating compressor operating at 30 psig suction, °0 superheat, °10 subcooling, 92% motor efficiency, year-round operation. Figure 1. The effect of rising head pressure.1. Check Refrigerant Pressures. Hook-up refrigerant gauges to the pressure ports on the unit. Blue --> "True Suction" Low Pressure. Red --> High Pressure (Small liquid line) Allow the unit to run for 5-10 minutes. Monitor pressures as the system operates. Normal R-22 Suction Pressure = 60 - 80psig. 2.High head pressure. Which of the following indicates air in a low-pressure system? To prevent freezing of water in the appliance. ... Charging liquid R245fa into a low-pressure refrigeration system under a vacuum greater than 18 inches Hg vacuum can cause the; 25 mm Hg absolute.The high flow increases the exit velocity of fluid leaving the pump, which in turn creates a low pressure area inside the pump. Operating to the left of BEP occurs when the discharge flow is restricted, causing fluid to re‐ ... Positive Suction Head (NPSH)—the pressure provided at the suction of the pump less the fluid’s vapor ...This small amount of heat to reject will cause a low condensing pressure and temperature. Most of the refrigerant will then be stored in the condenser and receiver, simulating a pumped-down refrigeration system. Symptoms of a liquid line restriction include: Low evaporator (suction) pressure; High superheats;Head pressure 190 Suction Pressure 90 Suction line temp 54 inside temp 75 wetbulb 69 So ive been thru this problem b4 with the low head high suction so i assume piston or a-coil . I open up the duct and the other hvac guy has put in a 3ton acoil . I told the neighbor that he should replace the acoil with a 2 1/2 ton .Watch on. Compression ratio is the ratio of head pressure to suction pressure in an HVAC/R unit. Generally, compression ratios approach 2.5:1 on high-efficiency, 16+ SEER A/C systems. The highest compression ratio in A/C compressors is typically 11:1. Refrigeration compression ratios tend to be quite a bit higher (up to 26:1).The yen weakened past 150 to the dollar Thursday, adding pressure on officials to intervene in the markets to shore up the currency. Jump to The Japanese yen weakened to above 150 ...1 Answer. Hi, High head and a low suction pressure can indicate a couple of different things. One, condenser coil very dirty and needs to be washed very well. This will bring your head pressure down but let it run back up to normal engine temperatures. If the head is ok after you clean it, and suction is even lower, you may still be low on charge.The human heart creates a pressure within the circulatory system every time it beats. Some people experience periods where their blood pressure is too high or too low. When blood M...so i just installed a brand new ac unit and its been kicking my butt.. but anways i put a 410a 1.5 ton 16 seer payne condenser with a 2 ton payne N coil with a txv already installed.. 155 suction pressure 280 discharge pressure 4 amps 10 degree sub cooling which condenser calls for only 3 degree superheat havent ran into a problem like this …The high head pressure may be due to ____. high ambient temperatures or reduced airflow through the condenser an overcharge of refrigerant, especially if it is a critically charged system Correct! All of the above. a thick coating of dirt and grime on the condenserJul 20, 2021 · An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ... HIGH SUCTION PRESSURE / LOW HEAD PRESSURE ISSUE. Hey guys, need some help i am working on a carrier unit with a Scroll Compressor. I am getting 80 PSIG low side and 165 PSIG high side. Liquid Line is also very hot to the touch. I know this is not normal readings and since it's a scroll compressor, I am thinking about replacing the TXV.Jul 19, 2005 · In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet. Our diagnostic sheet shows that liquid line restrictions cause low suction pressure and normal to low head pressure, not high head pressure. That’s because the compressor requires refrigerant of a specific density to pump refrigerant into the high side of the system; when the suction pressure is low, the compressor can’t move as much ... High head pressure B. High liquid level C. Low head pressure D. Low suction pressure A. High head pressure What is the typical design burst pressure for a rupture disk on a low-pressure centrifugal air-conditioning system. Low amp draw. Short cycle on low-pressure control (LPC). High Discharge Temperature Somewhat high discharge temperatures are caused from the higher superheats from the evaporator being starved of refrigerant. The compressor is now seeing a lot of sensible heat coming from the evaporator and suction line, along with its heat of … Terms in this set (54) In order for a system to operate correctly, the high side of the system must have enough _____. Vapor pumped, heat removed from condenser, vapor space. If there is a lack of refrigerant in a system, each pounds of refrigerant will not completely __________. Condense on the high side. When a system is undercharged, the ... Jun 24, 2011 · High Suction Pressure! I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and ... Low pulse pressure, or low blood pressure, is not always indicative of a health problem and it is usually not alarming to doctors unless the patient is exhibiting other symptoms ca...Low suction pressure and high head pressure occur when there’s a drop in refrigerant pressure in the AC system, coupled with elevated output pressure in the compressor. The primary culprit behind this condition is a …High discharge temperatures can indicate minimal movement of refrigerant. Because the refrigerant isn't being pumped at design rates it stays in the condenser for a longer period of time and is cooled more, hence lower head pressures, and in turn, if the compressor is not pumping well, you will see elevated suction pressures. Reply.410a low suction pressure high head pressure. Jump to Latest Follow 23K views 6 replies 2 participants last post by Dsmall07 Jun 19, 2013. D. Dsmall07 Discussion starter 4 posts · Joined 2013 Add to quote; Only show this user #1 · Jun 15, 2013. Have a 2 ton 410a hp running 75 suction & 365 head pressure od temp is 79 degrees suction …After the system runs for a while, raise the RPMs up to about 1,500. The system should be about 25 to 30 psi on the low side and 200 to 250 psi on the high side. If the ambient temperature is higher or lower than normal (70 to 80°F) the pressures will go up or down accordingly.Table 1: R134a Saturation Properties pressure table (Reference: www.chemours.com) Back to the problem at hand. For any refrigeration cycle/AC unit there are two operating pressures: suction pressure and discharging pressure, high and low settings for each pressure line determined by the manufacturer will stop the unit.Terms in this set (24) When a redfrigeration systems's suction line is noticeably cold instead of just being cool, it probably contains___refrigerent. low-pressure liquid. When a refrigeration systems's liquid linw is noticably hot instead of just being warm. probably contains ____ refrigerant. high-pressure vapor.Choose from our selection of high pressure water pumps, including air-powered constant-flow-rate pumps, gasoline-powered water-removal pumps, and more. ... Maximum Feet of Head. 98 ft. 100 ft. 103 ft. 110 ft. 115 ft. 125 ft. 3,679 ft. ... Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump ...This restriction will result in a pressure drop across the restriction. You'll have higher pressure on the inlet side and lower pressure on the outlet side of the “traffic jam.” ... we will see low suction pressure, high superheat, and normal to high subcooling. (Note: high head pressure isn't typically an indicator of a restriction!) In ...Low suction pressure in both mode. b. High head pressure in both mode. c. Low head pressure in the heat mode and high suction pressure in the cool mode. d. High head pressure in the heat mode and low suction pressure in the cool mode. D. If the reversing valve were to stick in the halfway position, which one of the following would the service ...180 suction line pressure 320 discharge 10 degree temp split. No temp difference across the filter drier. I cleaned coils and checked airflow just to eliminate the variables. I recovered the refrigerant, changed the filter drier, charged about 2lbs before starting the compressor and the low side shot right up to 170. System holds about 8 lbs total.Low suction pressure and high head pressure occur when there’s a drop in refrigerant pressure in the AC system, coupled with elevated output pressure in the compressor. The primary culprit behind this condition is a …Scale results in a low head pressure in the cooling mode and high suction pressure in the heating mode. False. A domestic hot water loop is loop is often used for heating domestic hot water from the hot discharge gas coming from the heat pump's refrigerant compressor. True.Walk-in freezer high head pressure. with the flip cover off and the outside roof temp near 100 deg, box is at 20 deg. I blew out all the dirt out of the condenser, and there was plenty, the high side does not sit still, it will fluctuate from 330-390, kicks off at 400, when it starts up, the high side immediately goes up for 5-10 seconds and ...Check the temperature difference in the suction line between low superheat and normal subcooling, which let’s say is 51°F in this example. Also, record the suction pressure, which is 70 psi (converts to 41°F using an R-22 temperature-pressure chart). Calculate the temperature difference: 51°F – 41°F = 10°F.I was working on a water source heat pump Trane serial number# W04C11546 MN# GEVB02411J0110TL. The unit is an upflow with the compressor compartment being on the bottom and the fan and coil on top. The problem is that the unit will run for about one minute in cooling mode then goes off on high head (400 psi r-22). …May 20, 2017 · Low suction/High head. I have a carrier 38QRF024300 with a 40QNQ024 unit I be been having issues with. Originally my readings were 157# suction (410A) and 275# head reading 7,5.2, and 4.1 amps when RLA is 12.8; with 5 degrees of subcooling. Ambient is 80 in parking garage. Check the temperature difference in the suction line between low superheat and normal subcooling, which let’s say is 51°F in this example. Also, record the suction pressure, which is 70 psi (converts to 41°F using an R-22 temperature-pressure chart). Calculate the temperature difference: 51°F – 41°F = 10°F.Subaru engines have a radiator and water channel design that uses pumped and pressurized coolant to stabilize its internal temperature. Unlike most internal combustion engines, ins...Jul 19, 2005 · In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet. Pumps operate by creating low pressure at the inlet which allows the liquid to be pushed into the pump by atmospheric or head pressure (pressure due to the liquid’s surface …LOL ok so it's 10 degrees of sub cooling that is low, sounds like you have a problem with the metering device. High amps, low sub cooling, low head pressure, high suction pressure, low temp drop across the evap. Your compressor is over the RLA so it's doing a lot of work, but with poor results, sounds like your flooding your evap.Posting Permissions. Today customer claims Liebert mini-mate has been locking out on high head pressure once or twice a month, sometimes more often, since it was installed approx. 1 year ago. The company that installed it has come out several times to check it out but found no high pressures.Upon examination, we found the system low on charge, cycling on the low pressure control. Repaired the leak, recovered refrigerant (because we didn't know what was in there). Evacuated to 500 microns and charged with HP62. Low side pressure is around 18psi and high side pressure is 375psi and tripping the high pressure cut out.The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.Study with Quizlet and memorize flashcards containing terms like In a 2-ton capillary tube system, the unit does not develop full capacity. Heat pressure is low and suction pressure is high. What is the problem?, In a 2-ton capillary tube system, the unit does not develop full capacity. Head pressure is high, suction pressure is high, and there is no …This small amount of heat to reject will cause a low condensing pressure and temperature. Most of the refrigerant will then be stored in the condenser and receiver, simulating a pumped-down refrigeration system. Symptoms of a liquid line restriction include: Low evaporator (suction) pressure; High superheats;Aug 29, 2023 · One of the leading causes of low suction pressure is refrigerant leakage. When refrigerant leaks occur, the system’s refrigerant charge decreases, resulting in reduced pressure levels. Leaks can occur at various points, including connections, joints, valves, or even within the coils themselves. 2. Dirty Evaporator or Condenser Coils. High head pressure B. High liquid level C. Low head pressure D. Low suction pressure A. High head pressure What is the typical design burst pressure for a rupture disk on a low-pressure centrifugal air-conditioning system.To diagnose a bad TXV, look for: Low evaporator pressure. High evaporator and compressor superheats. Low compressor amp draw. Short cycling on the low-pressure control. Higher than normal discharge temperatures. Low condensing pressure. Low condenser split. Normal to high condenser subcooling.R-22 Low Side Pressure 2: R-22 High Side Pressure 3 °F 1 °C: psig: kpa: Bar-50° ... Typical low pressure or suction side, may vary by equipment and metering controls - these are "gauge pressure readings" or "psig" Typical high …Jul 19, 2005 · In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet. Scale results in a low head pressure in the cooling mode and high suction pressure in the heating mode. False. A domestic hot water loop is loop is often used for heating domestic hot water from the hot discharge gas coming from the heat pump's refrigerant compressor. True.

Scale results in a low head pressure in the cooling mode and high suction pressure in the heating mode. False. A domestic hot water loop is loop is often used for heating domestic hot water from the hot discharge gas coming from the heat pump's refrigerant compressor. True.. O'block trial

low suction pressure high head pressure

This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control; Somewhat high discharge temperature; Low condensing (head) pressure; Low condenser split; and.Although cryptos enjoyed strong performances earlier, a lack of fundamental catalysts may apply some pressure on the sector. The fiat alternative narrative isn’t quite panning out ...Comparing head pressure with suction pressure reveals much about an HVAC unit. High or low readings indicate potential issues. Regular checks help catch problems early. For example, if head pressure is too high but suction remains normal, there might be a blockage. Conversely, low head pressure could suggest a leak somewhere in the system.Suction pressure: 110ish. head pressure: 400 reached 550 when I put my wind breaker over the top - Condenser coil was clean. Subcooling: 50. Superheat: 35. Liquid line temp: 68. Suction line temp: 63. Even temps at both sides of the filter drier. Reply. 06-11-2020, 04:58 PM #2.Nov 11, 2016 · Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from ... We would like to show you a description here but the site won’t allow us. normal suction low head pressure. im in the field 3 years now and this is the first time ive come across this. residential split system 1.5 tons and i had a good suction pressure but my head pressure was super low, only 150-160. the strange thing is operations seemed pretty normal. cold suction line, warm liquid line, condenser was …Upon examination, we found the system low on charge, cycling on the low pressure control. Repaired the leak, recovered refrigerant (because we didn't know what was in there). Evacuated to 500 microns and charged with HP62. Low side pressure is around 18psi and high side pressure is 375psi and tripping the high pressure cut out.A bad check valve on an air conditioner, heat pump or similar HVACR equipment can show up as abnormally low or abnormally high suction line pressures, or as abnormally low or high superheat. Experts suggest using an IR heat gun or similar tempeature measuring tool to check the tempeature of the refrigerant line on each side of the valve.Advertisement ­C­lusters are now being used on a smaller scale for sensors. For instance, a traditional pressure sensor contains a device that outputs a varying voltage depending o...After the system runs for a while, raise the RPMs up to about 1,500. The system should be about 25 to 30 psi on the low side and 200 to 250 psi on the high side. If the ambient temperature is higher or lower than normal (70 to 80°F) the pressures will go …How to Fix Low Suction Pressure Issues. If there is excessive moisture in system: replace the drier. If you find a flattened or kinked hose: replace the hose. If the compressor pistons have worn out: replace the compressor. If there is a shortage of refrigerant: add refrigerant. If there is a leaking compressor head gasket: replace the head gasket.Technician saw pressure fluctuations of 450-580 or so high side and a 10 psi range on low side centered around 132 or so. Oddly, they shot to their highs together, bled down to the lows over about 40 seconds, shot back up, ad infinitum.Aug 1, 2013 · The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is running in the proper direction. Reply. In this HVAC Refrigerant Charging Video I go over what it means to have low R22 Freon or Low R410A Suction Vapor Pressure along with a Low Superheat. I expla...Failed suction pressure transducer (SPT) Replace. No evaporator air flow or restricted air flow. Section 7.11. Excessive frost on evaporator coil. Section 6.6. EEV control malfunction. Section 7.14. Loose or insufficiently clamped sensor (ETS) Replace. High suction pressure with low su­perheat. Foreign material in valve. Section 6.11One of the leading causes of low suction pressure is refrigerant leakage. When refrigerant leaks occur, the system’s refrigerant charge decreases, resulting in reduced pressure levels. Leaks can occur at various points, including connections, joints, valves, or even within the coils themselves. 2. Dirty Evaporator or Condenser Coils.HVAC REFRIGERATION TROUBLESHOOTINGLOW SUCTION/LOW HEAD PRESSURE1. check air flow obstruction2. check dirty evaporator3. check dirty air filter4. check for a ...R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol. R22 gas cylinder identification: light green. R2 status: no longer in active use, replaced with R458A.HIGH SUCTION PRESSURE / LOW HEAD PRESSURE ISSUE. Hey guys, need some help i am working on a carrier unit with a Scroll Compressor. I am getting 80 PSIG low side and 165 PSIG high side. Liquid Line is also very hot to the touch. I know this is not normal readings and since it's a scroll compressor, I am thinking about replacing the TXV..