High suction pressure and low head pressure - This small amount of heat to reject will cause a low condensing pressure and temperature. Most of the refrigerant will then be stored in the condenser and receiver, simulating a pumped-down refrigeration system. Symptoms of a liquid line restriction include: Low evaporator (suction) pressure; High superheats;

 
If you don't mind getting your hands a little dirty, some petroleum jelly can increase the suction power of your plunger to help with particularly stubborn clogs. If you don't mind.... Half life of nyquil

Typical low pressure or suction side pressure for R410A is about 120 psi, varying by ambient temperature, here assuming 75°F, may vary by equipment and metering …A few months ago A/C repair company found high suction pressure & low head pressure. Replaced a valve in air handler. System is a 2 y/o, 5 ton Trane heat pump. This spring a/c doesn't seem to be cooling the house well. A different A/C company tells me my pressures are way off and shows me a bad valve that should be replaced.If you own a Waterpik and are experiencing low pressure issues, don’t worry – you’re not alone. Low pressure can be frustrating, but luckily, there are several troubleshooting step...I will be sharing a pressure chart that may help you troubleshoot low pressure symptoms, high pressure symptoms. As well as other potential problems you may run into when trying to get your r410a or r22 systems to normal operating pressures. ... Outside air temp 95. Running for an hour, suction 120, head pressure between 315-350. Fluctuates ...Many car audio stereo receivers on the market feature an integrated and user-adjustable crossover system, designed to route certain sound frequency ranges to specific speakers conn...180 suction line pressure 320 discharge 10 degree temp split. No temp difference across the filter drier. I cleaned coils and checked airflow just to eliminate the variables. I recovered the refrigerant, changed the filter drier, charged about 2lbs before starting the compressor and the low side shot right up to 170. System holds about 8 lbs total.Positive Suction Head (NPSH)—the pressure provided at the suction of the pump less the fluid’s vapor pressure — is too low. When fluid pressure on the trailing side of the impeller blade (opposite the pump intake) falls below the vaporization point of the fluid, vapor bubbles begin to form.Number 2 is incorrect, metering device part depends on system to system. High load is correct. Look at your liquid line temps, subcooling and approach temps. They will help diagnose high head issues. There is another cause of high head pressure, mismatched (higher btu) compressor. Different refrigerant in the system.The normal operating pressure for R-404A in a freezer at a temperature of 70 degrees Fahrenheit and a suction temperature of 30 degrees Fahrenheit would be around 9.6 psi. The low pressure should be 18-20 psi while the high pressure should be around 200 psi. However, this can vary depending on the specific conditions of the freezer and the ...Suction head = h s = p s / ρg + v s2 / 2 g. From the definition of vapor pressure head, Vapor pressure head = h v = p v / ρg. In the simplest language, we can say, NPSH = Pressure head at the inlet or suction – vapor pressure head. Let’s see the formula or equation of NPSH, NPSH = hs – hv.Positive Suction Head (NPSH)—the pressure provided at the suction of the pump less the fluid’s vapor pressure — is too low. When fluid pressure on the trailing side of the impeller blade (opposite the pump intake) falls below the vaporization point of the fluid, vapor bubbles begin to form. HIGH SUCTION PRESSURE / LOW HEAD PRESSURE ISSUE. Hey guys, need some help i am working on a carrier unit with a Scroll Compressor. I am getting 80 PSIG low side and 165 PSIG high side. Liquid Line is also very hot to the touch. I know this is not normal readings and since it's a scroll compressor, I am thinking about replacing the TXV. Net Positive Suction Head. Net Positive Suction Head or NPSH for pumps can be defined as the difference between the suction pressure and the saturation pressure of the fluid, expressed in terms of height of liquid column. NPSH is used to measure how close a fluid is to saturated conditions. Lowering the pressure at the …The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.A dirty evaporator in an air conditioning system will cause what symptoms? Low Suction and Low Head Pressure (discharge) Technician "A" says that a compressor should pull 24" Hg during a vacuum test with 100 psig discharge pressure. Technician "B" says that a compressor should pull 26" hg to 28" Hg when discharging to the atmosphere.Cause #1 Return Duct Leakage:. The suction pressure can be high if the room temp is high, or the return duct has leaks. Cause #2 TXV Improperly feeding: Cause#3 Outdoor/Indoor coil dirty: low airflow situations can cause refrigerant to not completely condense into a liquid, or turn into a gas Cause #4 Unit is Overcharged: One …High discharge temperatures can indicate minimal movement of refrigerant. Because the refrigerant isn't being pumped at design rates it stays in the condenser for a longer period of time and is cooled more, hence lower head pressures, and in turn, if the compressor is not pumping well, you will see elevated suction pressures. Reply.Low suction pressure causes. low suction pressure is developed in the refrigeration system. Some of the most probable causes are as below, The coil is covered with dust or frost. Restriction in the refrigerant line. Filters and strainers are dirty. Faulty fan motor. Low room temperature. Faulty compressor.A dirty evaporator in an air conditioning system will cause what symptoms? Low Suction and Low Head Pressure (discharge) Technician "A" says that a compressor should pull 24" Hg during a vacuum test with 100 psig discharge pressure. Technician "B" says that a compressor should pull 26" hg to 28" Hg when discharging to the atmosphere.The suction pressure, also known as the low-side pressure, for a 404A cooler typically falls between 55-70 psi. This pressure ensures that the refrigerant evaporates at the desired temperature in the evaporator, providing efficient cooling. ... What causes high head pressure on a walk-in cooler? High head pressure in a walk-in cooler can be ...Resetting the low-tire light on the Subaru Outback will turn the low-tire-pressure light off. Resetting can normally only be done properly with a diagnostic reset tool that you can...R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.If you own a Waterpik and are experiencing low pressure issues, don’t worry – you’re not alone. Low pressure can be frustrating, but luckily, there are several troubleshooting step...Cause #1 Return Duct Leakage:. The suction pressure can be high if the room temp is high, or the return duct has leaks. Cause #2 TXV Improperly feeding: Cause#3 Outdoor/Indoor coil dirty: low airflow situations can cause refrigerant to not completely condense into a liquid, or turn into a gas Cause #4 Unit is Overcharged: One …The high side guage was connected to the liquid line. Static, both guages are 160 psig. When the unit ran, BOTH guages dropped to about 130. The high side was perhaps 2-5 higher. The amp draw at the compressor was 8.6 RLA out of a 22.1 suggest maximum on the equipment sticker.Low suction pressure causes. low suction pressure is developed in the refrigeration system. Some of the most probable causes are as below, The coil is covered with dust or frost. Restriction in the refrigerant line. Filters and strainers are dirty. Faulty fan motor. Low room temperature. Faulty compressor.Hi, I just put a new compressor on a gas pack. I charged it to the correct amount of refrigerant o the name tag. My ambient temp. is 100 degrees and the unit running with a high high side pressure a high suction pressure and high superheat and sub cooling. The indoor temp is 87 degrees. i was told that the high indoor temp is why my …The users should set high and low alarms on the EdP output to keep the DP tightly controlled while increasing the flow rate. If the pump doesn’t generate 120 feet total head at the 55 gpm flow rate, this could be your first indication of an operational or mechanical issue. Check the suction pressure and ensure it is greater than NPSHr.The compressor is still cooling, but not to its rated capacity, which can cause refrigerated products to spoil faster and frozen products to begin to thaw. There are three main reasons why a compressor will simultaneously have a low head pressure and a high suction pressure: 1. Bad (leaky) compressor valves; 2. Worn compressor rings; and.We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be …problems. Fluid flows from areas of high pressure to areas of low pressure. Pumps operate by creating low pressure at the inlet which allows the liquid to be pushed into the pump by atmospheric or head pressure (pressure due to the liquid’s surface being above the centerline of the pump). Consider placing a pump at the top of the mercuryIt's tempting to head to the Caribbean this winter but here's why you might want to avoid the trip -- even to islands with low COVID-19 infection rates. Editor’s note: This post ha...1. Reduced Cooling Capacity. 2. Reduced Airflow From the Vents. 3. Increased Energy Consumption. 4. Poor Indoor Air Quality. How to Diagnose and Fix Low Suction Pressure High Head Pressure. Step 1: Inspect the System for Leaks. Step 2: Measure the Pressure and Temperature. Step 3: Replace or Repaire Components. Add Proper Refrigerant.This small amount of heat to reject will cause a low condensing pressure and temperature. Most of the refrigerant will then be stored in the condenser and receiver, simulating a pumped-down refrigeration system. Symptoms of a liquid line restriction include: Low evaporator (suction) pressure; High superheats;High Head Pressure. High head pressure is typically accompanied by a low suction pressure. This combination can be indicative of restricted refrigerant. Essentially, this means that air and vaporized water travel through your HVAC’s evaporator until they get to the top of the compressor, where it remains because it will not condense.Often the heavy-duty equipment is needed high discharge pressure and low suction pressure. Because of low pressure at the suction side of the pump, fluid lifts from a certain depth, whereas because of high pressure at the discharge side of the pump, it pushes the fluid to lift, until it reaches the desired height. Types of PumpsRepeatedly tripping sentronic+. 35 psi net oil press. No press difference between crank and suction. Crankcase heater working. R-22 40 psig suction 160 psig head, 8* sh at comp. sorry no sc data. 40* outdoor ambient. Sh measurements taken at each evap outlet right around 4*. No one evap showing major flooding.One of the leading causes of low suction pressure is refrigerant leakage. When refrigerant leaks occur, the system’s refrigerant charge decreases, resulting in reduced pressure levels. Leaks can occur at various points, including connections, joints, valves, or even within the coils themselves. 2. Dirty Evaporator or Condenser Coils.Lowering the head pressure will result in an increase in the frequency and magnitude of the surge. Conversely, increasing the head pressure will result in lower frequency and magnitude. With a melt pump, simply lowering and raising the suction pressure will give you an indication if a partially filled metering section is the problem, if …what causes a high suction pressure and a normal head presssure on an r22 system besides low air across the evaporator coil? Can air in the system cause this situation? TD is 17f. otd is 91degrees liquid line pressure is 230psi; suction pressure is 90psi.The yen weakened past 150 to the dollar Thursday, adding pressure on officials to intervene in the markets to shore up the currency. Jump to The Japanese yen weakened to above 150 ...lower suction pressure and high discharge pressure. Study with Quizlet and memorize flashcards containing terms like which of the following is NOT a symptom of a hermetic system that is low on refrigerant?, frost on the suction line indicates;, an increase in head pressure causes _____ refrigerant to flow through a capillary tube. and more.If you have high blood pressure or heart, liver, or kidney problems, your health care provider may suggest you lower your sodium intake. Look for these words on labels: low-sodium,...When a refrigeration system that produces low or no cooling has high suction pressure and high head pressure , it probably A. has an inefficient compressor B. has a low-side restriction C. is overcharged D. is undercharged. Refrigeration and Air Conditioning Technology (MindTap Course List) 8th Edition. ISBN: 9781305578296.• High suction pressure/Up-thrust: Patent pending dual bearing arrangement that handles rotor up-thrust and to keep the shaft ... High-Head/Low Flow Services • Capacities 20 GPM (6.8m3/hr) to 2,800 GPM (636 m3/hr) • Heads to 4500 feet (1372 meter)*Head pressure 190 Suction Pressure 90 Suction line temp 54 inside temp 75 wetbulb 69 So ive been thru this problem b4 with the low head high suction so i assume piston or a-coil . I open up the duct and the other hvac guy has put in a 3ton acoil . I told the neighbor that he should replace the acoil with a 2 1/2 ton .Peal. 3 posts · Joined 2009. #46 · Jul 12, 2009 (Edited) I think bwalley is correct. 3 things will cause high head pressure; poor air flow across condenser, overcharge, or non condensable in system. Recover charge, check system for leaks, pull vacuum, and weigh in new charge.Hi all (yall) I was doing a PM for a customer and when taking the refrigerant readings, I have come to a complete brain fart as to why the system was doing this. Readings: Indoor temp: 70 F. Outdoor temp: 68 F. Suction Pressure: 65 PSIG (roughly 10 degrees) Discharge Pressure: 205 PSIG (roughly 72 degrees)The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is running in the proper direction. Reply.Hi, sorry you're having trouble. Low suction and high head is usually due to a restriction in the liquid line. Basically, you're starving the evaporator. If the unit has an expansion valve on the inlet to the evaporator, it may be defective. Some are adjustable, most residential ones, not. I would look there first.Reduced system performance. Increased energy consumption. Impact of High Head Pressure. Excessively high head pressure can:• High suction pressure/Up-thrust: Patent pending dual bearing arrangement that handles rotor up-thrust and to keep the shaft ... High-Head/Low Flow Services • Capacities 20 GPM (6.8m3/hr) to 2,800 GPM (636 m3/hr) • Heads to 4500 feet (1372 meter)*The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.Head pressure 190 Suction Pressure 90 Suction line temp 54 inside temp 75 wetbulb 69 So ive been thru this problem b4 with the low head high suction so i assume piston or a-coil . I open up the duct and the other hvac guy has put in a 3ton acoil . I told the neighbor that he should replace the acoil with a 2 1/2 ton .Are you confused about all the different blood pressure readings? You aren’t alone. Read this quick guide to learn more about the difference between systolic and diastolic, what no...The most common, and obvious, reason for a service call is a space temperature that is too warm. And, just as common, is suction pressure and/or head pressure being involved in the cause. Often, the refrigeration system will still run, but it’ll run inefficiently because the suction pressure is too high while the head pressure is ...So we replace the compressor (same model #), replace the liquid line filter dryer, and evacuate to 500 microns. I weigh the charge in per the manual = unit's orignal charge + addl ounces per foot of lineset - total of 5# 6 oz. Start unit up, damn it, looks wrong immediatelY: Suction: 149.5 psi. Suction Temp: 55.4*F.It is possible to ensure that cavitation is avoided during pump operation by monitoring the net positive suction head of the pump. Net positive suction head for a pump is the difference between the suction pressure and the saturation pressure of the fluid being pumped. NPSH is used to measure how close a fluid is to saturated conditions ...Jack Ma's Ant Group and Alibaba have come under increasing regulatory pressure from Chinese authorities in recent months. Jump to Alibaba jumped as much as 5% on Tuesday after CNBC...Bombogenesis happens when the atmospheric pressure in a low-pressure system drops rapidly, intensifying a storm and creating a bomb cyclone. Advertisement This planet has a lot of ...I have a suction pressure of 70, converted temp of 41, suction line temp of 51, head pressure of 250, converted temp of 117, head line temp of 96. Air entering condenser is 82 and exit is 100. Air entering evaporator is 76 and exiting is 52.Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. 66.2 low side line temp. High side pressure: 335psi = 104 saturation temp. 83.1 high side line temp. Temp at the vent in rooms: 56.1F + or minus. Temp from supply side: 55.2F.Peal. 3 posts · Joined 2009. #46 · Jul 12, 2009 (Edited) I think bwalley is correct. 3 things will cause high head pressure; poor air flow across condenser, overcharge, or non condensable in system. Recover charge, check system for leaks, pull vacuum, and weigh in new charge.If suction pressures are low and the temperatures are close to freezing, the next step is to take the remaining measurements of your 5 Pillars (superheat, …This is a low-pressure bypass from the liquid system, as well as high back and low head pressures. What should be the 410a suction pressure? As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A.R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.Faulty valves in an open-drive compressor ____. will lead to compressor inefficiency may cause high suction pressure and low head pressure are serviceable by a manufacturer-approved repair facility All of the above. vibration absorber, a filter-drier, and an accumulator. A suction line may also contain a ____. vibration absorber, ...This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control; Somewhat high discharge temperature; Low condensing (head) pressure; Low condenser split; and.External to the compressor are numerous other alarm and shutdown safeguards. As a minimum, low lube oil pressure, low seal gas pressure differential, overspeed, high discharge gas temperature, high and low suction and discharge pressures, and high liquid level in the suction scrubber are monitored and will initiate a …In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet.If the system suction pressure on a fixed metering device type unit is too high; the potential causes are; C. Flooded Evaporator Coil, High Evaporator Head Load, Dirty Condenser Coils, Compressor Valve Failures. TXV system problems can exhibit the five following symptoms: a. Normal suction pressure & superheat, with low or high …Pump characteristics—such as flow, pressure, efficiency and brake horsepower—are shown graphically on a pump curve. The first item to look at is the size of the pump. The size of the pump, 2x3-8 is shown in the upper section of the graph. The numbers 2x3-8 indicates: The outlet (discharge port) is 2 inches.so i just installed a brand new ac unit and its been kicking my butt.. but anways i put a 410a 1.5 ton 16 seer payne condenser with a 2 ton payne N coil with a txv already installed.. 155 suction pressure 280 discharge pressure 4 amps 10 degree sub cooling which condenser calls for only 3 degree superheat havent ran into a problem like this …If the motor turns the wrong way, the impeller could potentially back off the shaft, causing serious damage to the internals. 2. Clogged Suction. Make sure the suction pipe is free and clear of debris. Less flow into the pump, will obviously yield less flow out of the pump. 3. Worn impeller, wear ring, wear plate.Low Load. While we often think of the combo of low suction, superheat, and head pressure as being caused by low airflow, it actually falls under a larger heading of low evaporator load. That simply means that the quantity of heat being picked up in the evaporator is lower than the refrigerant mass flow rate requires for the desired operation.One of the leading causes of low suction pressure is refrigerant leakage. When refrigerant leaks occur, the system’s refrigerant charge decreases, resulting in reduced pressure levels. Leaks can occur at various points, including connections, joints, valves, or even within the coils themselves. 2. Dirty Evaporator or Condenser Coils.lower suction pressure and high discharge pressure. Study with Quizlet and memorize flashcards containing terms like which of the following is NOT a symptom of a hermetic system that is low on refrigerant?, frost on the suction line indicates;, an increase in head pressure causes _____ refrigerant to flow through a capillary tube. and more.Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on …A ratio of head pressure to suction pressure is your compression ratio. Higher compression ratios tend to lead to reduced compressor performance (moving fewer BTUs). Even though we tend to see high head pressure as the main problem to avoid, we should be aware that low head pressure is possible.Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from ...higher head pressure and higher subcooling. When any refrigeration system is low on refrigerant it will usually have: low suction and low head pressure. What can cause high superheat in a TEV metered evaporator? ... What combination of symptoms only occurs on a unit with an inefficient compressor? Low head pressure and high suction pressure ...High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps.I have a suction pressure of 70, converted temp of 41, suction line temp of 51, head pressure of 250, converted temp of 117, head line temp of 96. Air entering condenser is 82 and exit is 100. Air entering evaporator is 76 and exiting is 52.Hepatic ischemia is a condition in which the liver does not get enough blood or oxygen. This causes injury to liver cells. Hepatic ischemia is a condition in which the liver does n...Lower suction pressures generally result in a higher DTD, and higher suction pressures usually result in a lower DTD. When we look at head pressure, we’re actually learning …The most common, and obvious, reason for a service call is a space temperature that is too warm. And, just as common, is suction pressure and/or head pressure being involved in the cause. Often, the refrigeration system will still run, but it’ll run inefficiently because the suction pressure is too high while the head pressure is ...What is High Head Pressure for 410A . High head pressure for 410A is an indication of a system that has lost its ability to evaporate refrigerant correctly. This can be caused by many things including low charge, clogged air filters, restricted airflow, or dirty coils. High head pressure creates higher discharge temperatures and forces the ...

A bad check valve on an air conditioner, heat pump or similar HVACR equipment can show up as abnormally low or abnormally high suction line pressures, or as abnormally low or high superheat. Experts suggest using an IR heat gun or similar tempeature measuring tool to check the tempeature of the refrigerant line on each side of the valve.. Bert kreischer alcohol

high suction pressure and low head pressure

If you don't mind getting your hands a little dirty, some petroleum jelly can increase the suction power of your plunger to help with particularly stubborn clogs. If you don't mind...Lower suction pressures generally result in a higher DTD, and higher suction pressures usually result in a lower DTD. When we look at head pressure, we’re actually learning …Positive Suction Head (NPSH)—the pressure provided at the suction of the pump less the fluid’s vapor pressure — is too low. When fluid pressure on the trailing side of the impeller blade (opposite the pump intake) falls below the vaporization point of the fluid, vapor bubbles begin to form.If suction pressures are low and the temperatures are close to freezing, the next step is to take the remaining measurements of your 5 Pillars (superheat, …One of the leading causes of low suction pressure is refrigerant leakage. When refrigerant leaks occur, the system’s refrigerant charge decreases, resulting in reduced pressure levels. Leaks can occur at various points, including connections, joints, valves, or even within the coils themselves. 2. Dirty Evaporator or Condenser Coils.Your blood pressure readings are useful indicators of your cardiovascular system’s overall health. Low, high and normal blood pressure readings help your doctor make the right deci...When a refrigeration system that produces low or no cooling has high suction pressure and high head pressure , it probably A. has an inefficient compressor B. has a low-side restriction C. is overcharged D. is undercharged. Refrigeration and Air Conditioning Technology (MindTap Course List) 8th Edition. ISBN: 9781305578296.The most common liquid line restrictions are clogged filter-driers, metering device inlet screens, a kinked liquid line, or a TXV with an empty bulb. These very rarely cause high head for more than a short period of time. The most common causes of high head pressure include high load, overcharge, and poor heat rejection (such as from …Note that variations in the atmospheric pressure can and will affect the NPSHa value. Now you just need to convert the atmospheric pressure from psia to feet of head. Multiply 14.7 by 2.31, and the result is 33.957 feet, rounding to 34 feet. The value for the first component in the equation is 34 feet.Blog. Pressure Points: Understanding the Importance of Head Pressure in HVAC. December 20, 2023by J & J Services. Table of ContentsToggle. Causes of High …Low amp draw. Short cycle on low-pressure control (LPC). High Discharge Temperature Somewhat high discharge temperatures are caused from the higher superheats from the evaporator being starved of refrigerant. The compressor is now seeing a lot of sensible heat coming from the evaporator and suction line, along with its heat of …Try our Net positive suction head calculator or: In your reservoir, get fluid surface pressure: P surface. Get the distance between the pump and liquid surface: Z. If the tank is above the pump, multiply this value by -1. Obtain the vapor pressure for the system's temperature: P vapor. Also, its density is ρ. Note that g represents gravity.An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up …Low suction/High head. I have a carrier 38QRF024300 with a 40QNQ024 unit I be been having issues with. Originally my readings were 157# suction (410A) and 275# head reading 7,5.2, and 4.1 amps when RLA is 12.8; with 5 degrees of subcooling. Ambient is 80 in parking garage.Repeatedly tripping sentronic+. 35 psi net oil press. No press difference between crank and suction. Crankcase heater working. R-22 40 psig suction 160 psig head, 8* sh at comp. sorry no sc data. 40* outdoor ambient. Sh measurements taken at each evap outlet right around 4*. No one evap showing major flooding.Our diagnostic sheet shows that liquid line restrictions cause low suction pressure and normal to low head pressure, not high head pressure. That’s because the compressor requires refrigerant of a specific density to pump refrigerant into the high side of the system; when the suction pressure is low, the compressor can’t move as much ....